<LOGO>
FM Transmitter Measurement Report
Created: 2025-10-17 02-07-55
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
97.30 MHz 5/5, 70 dBuV YLESUOMI
Pilot RDS Phase Difference
7.1 kHz 3.7 kHz 73 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 66 kHz 19059 3,6203
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,3 dBr 4,54 dBr 5,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"YLESUOMI" 6203 9 (Varied) 1 0 1 1 2:07, 17.10.2025
RT
"ILTA "
AF EON
95.6, 97.3, 98.4, 98.6, 98.9, 99.2, 102.5 MHz 6207, 6205, 6201, 6202
FM Scope Max at: 66 kHz MIN: 10 kHz % above 76 kHz: 3,6203 Acquired: 2025/10/17 2.06.51 Total samples: 19059 Equivalent time: 0:15:52 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 500 1000 1500
FM Scope MAX: 5,6 dBr MIN: 2,3 dBr AVE: 4,54 dBr % above 12,2 dBr: 0,0 Last value: 3,4 dBr (2025/10/17 2.06.50) 01.52 01.54 01.56 01.58 02.00 02.02 02.04 02.06 0 2 4 6 Pm [dBr]